Control Cable, With Shield Foil

Control Cable › With Shield Foil + Braid


With Shield Foil › IB... Multiconductors

  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor
Fine stranded concentric bare copper
Insulation
105°C PVC optional PE, XLPE, PP
Shield
100% coverage, aluminium polyester foil shield and 85% of copper braided
Drain Wire
7 strands tinned copper
Jacket
Black sunlight resistant PVC
Application
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602 . ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
IB035xx 22 AWG, 0.35 sqmm. DCR 55.4 ohm/km Control Cable, With Shield Foil
IB050xx 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km Control Cable, With Shield Foil
IB075xx 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km Control Cable, With Shield Foil
IB100xx 17 AWG, 1.00 sqmm. DCR 17.4 ohm/km Control Cable, With Shield Foil
IB125xx 16 AWG, 1.25 sqmm. DCR 14.3 ohm/km Control Cable, With Shield Foil
IB150xx 15 AWG, 1.50 sqmm. DCR 10.8 ohm/km Control Cable, With Shield Foil
IB250xx 13 AWG, 2.50 sqmm. DCR 6.82 ohm/km Control Cable, With Shield Foil
IB400xx 11 AWG,4.0 sqmm. DCR 4.33 Ohm/km Control Cable, With Shield Foil
IB600xx 9 AWG, 6.0 sqmm DCR 2.7 Ohm/km Control Cable, With Shield Foil


With Shield Foil › IB...(P) Multipairs

Control Cable, With Shield Foil
  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor:
Fine stranded concentric bare copper
Insulation:
105°C PVC optional PE, XLPE, PP
Construction
Twisted pairs construction, traids and quads twisted also available
Shield
100% coverage aluminium polyester foil shield and 85% of copper braided
Drain Wire
7 strands tinned copper
Jacket:
Black sunlight resistant PVC
Application:
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602. ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
IF050xxP 20AWG, 0.50 sqmm. DCR 34.4 Ohm/km Multipairs
IF075xxP 18 AWG,0.75 sqmm. DCR 21.9 Ohm/km Multipairs Control Cable, With Shield Foil
IF125xxP 16 AWG,1.25 sqmm. DCR 13.7 Ohm/km Multipairs Control Cable, With Shield Foil

With Shield Foil › IBI...(P) Individual Foil

Control Cable, With Shield Foil
  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor:
Fine stranded concentric bare copper
Insulation:
105°C PVC optional PE, XLPE, PP
Construction
Twisted pairs construction, traids and quads twisted also available
Shield
100% coverage aluminium polyester foil shield
Drain Wire
7 strands tinned copper
Jacket:
Black sunlight resistant PVC
Application:
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602. ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
IBI050xxP 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km Multipairs Control Cable, With Shield Foil
IBI075xxP 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km Multipairs Control Cable, With Shield Foil
IBI125xxP 16 AWG, 1.25 sqmm. DCR 13.7 ohm/km Multipairs Control Cable, With Shield Foil