Control Cable › With Shield Foil

With Shield Foil › IF... Multiconductors.

  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor:
Fine stranded concentric bare copper
Insulation:
105°C PVC optional PE, XLPE, PP
Jacket:
Black sunlight resistant PVC
Application:
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602. ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
IF035xx 22 AWG, 0.35 sqmm. DCR 55.4 ohm/km
IF050xx 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km
IF075xx 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km
IF100xx 17 AWG, 1.00 sqmm. DCR 17.4 ohm/km
IF125xx 16 AWG, 1.25 sqmm. DCR 13.7 ohm/km
IF150xx 15 AWG, 1.50 sqmm. DCR 10.8 ohm/km
IF250xx 13 AWG, 2.50 sqmm. DCR 6.82 ohm/km


With Shield Foil › IF...(P) Multipairs

  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor:
Fine stranded concentric bare copper
Insulation:
105°C PVC optional PE, XLPE, PP
Construction
Twisted pairs construction, traids and quads twisted also available
Shield
100% coverage aluminium polyester foil shield
Drain Wire
7 strands tinned copper
Jacket:
Black sunlight resistant PVC
Application:
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602. ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
IF050xxP 20AWG, 0.50 sqmm. DCR 34.4 Ohm/km Multipairs
IF075xxP 18 AWG,0.75 sqmm. DCR 21.9 Ohm/km Multipairs
IF125xxP 16 AWG,1.25 sqmm. DCR 13.7 Ohm/km Multipairs

With Shield Foil › IFI...(P) Individual Foil

  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor:
Fine stranded concentric bare copper
Insulation:
105°C PVC optional PE, XLPE, PP
Construction
Twisted pairs construction, traids and quads twisted also available
Shield
100% coverage aluminium polyester foil shield
Drain Wire
7 strands tinned copper
Jacket:
Black sunlight resistant PVC
Application:
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602. ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
IFI050xxP 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km Multipairs
IFI075xxP 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km Multipairs
IFI125xxP 16 AWG, 1.25 sqmm. DCR 13.7 ohm/km Multipairs